Marine Advisory: 28/2020 - South Korea’s Designation of Emission Control Areas

Edition
28/2020
Last updated

27 August 2020

Marine Advisory 28/2020

27 August 2020

Marine Advisory: 28/2020

Subject: South Korea’s Designation of Emission Control Areas

Reference:

  1. Incheon Port Authority Guidance
  2. Pyeongtaek Port Authority’s Guidance

Dear Shipowners/Operators/Masters

Purpose: This Advisory is sent to inform Liberian vessel operators that the South Korean Ministry of Oceans and Fisheries (MOF) has recently announced the designation of SOx Emission Control Areas (SECA) in accordance with the “Special Act on the Improvement of Air Quality in Port Areas, etc.” which was enacted in 2019.

Requirements:

  1. Reduction of SOx Emission from ships

Ships in the SOx Emission Control Areas are required to use fuel oil with sulphur content not exceeding 0.1% m/m, or install an appropriate exhaust gas cleaning system (EGCS) to reduce SOx emissions to 4.3 (unit: SO2 (ppm) / CO2 (%, v/v)) or less.

  1. Recording in Engine Log Book in SECA

Ships operating inside the SECAs shall record the fuel oil change-over, etc. in the engine log book, or alternatively record the operation status of the EGCS. Also, the ships shall keep the above engine log book on board for a period of not less than 12 months from the time of delivery of the fuel oils to the ship.

Applicable ships

Entries to be recorded in Engine Log Book

Ships using low sulphur fuel oil

(not exceeding

0.1%)

  1. Type of fuel oil, date, time, and ship's position (place) when the fuel oil change-over is completed.
  2. Volume of low sulphur fuel oil (sulphur content of 0.1% or less) remaining in each fuel oil tank.
  3. Sulphur content of fuel oil (for the most recently supplied fuel oil)

Ships equipped with an EGSC

Scheme A

Result of check

Parameters prior to entering an Emission Control Area

Scheme B

SO2(ppm)/CO2(%,v/v) ratio prior to entering an Emission Control Area

Both

Time and position of switching operational mode on exhaust gas cleaning system prior to entering an Emission Control Area

  1. Fuel change-over procedure

Those ships using separate fuel oils stored in separate tanks (to comply with sulphur content limit requirements) shall carry written procedure showing how the fuel oil change-over is to be done before entering or leaving a SECA in Korea.

Application:

Applicable ships

Range of application

Date of

Enforcement

Ships anchoring or mooring in

SECA

From 1 hour after completion of anchoring or mooring to 1 hour before completion of heaving in anchor or unberthing

From 1st September,

2020 to 31st December 2021

All ships

From entry into SECA until the exit from SECA

On or after

1st January, 2022

Sulphur Emission Control Area:

Incheon,

Pyeongtaek,

Dangjin

Yeosu, Gwangyang

Busan

Busan (West)

Ulsan

Within the boundary of below points

Within the boundary of below points

Within the boundary of below points

Within the boundary of below points

6 miles from

37°36'00"

126°33'42"

34°35'24"

127°48'20"

35°09'36"

129°11'32"

35°03'19.5"

128°43'23.5

35°24'37"

129°27'52"

37°10'00"

126°06'30"

34°35'24"

128°00'26"

35°09'04"

129°11'44"

34 °58'30"

128°45'21"

37°02'54"

126°29'00"

34°42'42"

128°00'26"

34°58'46"

129°04'14"

34°55'00"

128°50'00"

34°56'22"

127°52'06"

34°55'00"

128°50'00"

34°58'41.5"

128°49'19.5

34°56'46"

127°51'56"

34°58'41.5"

128°49'19.5

35 °02'01.4"

128°47'37.8

"35 °02'01.4"

128°47'37.8

"35 °03'19.5" 128°43'23.5"

35°03'19.5"

128°43'23.5”

35°05'42"

128°42'53"

Please contact RegsandStandards@liscr.com if you have any questions.

* * * * * *